Application
Today in power plants, high pressure boilers and steam turbines are under constant attack from erosive and corrosive elements such as Silica, Sodium, Dissolved Oxygen, Calcium, Chloride and Phosphates. Without accurate measurement and monitoring, the plant may suffer heavy mechanical damages that can be caused due to imbalance of turbines, reduced efficiency, deposition on turbine blades, corrosion of steam pipe work and so on.
Benefits
Design
Starting with a mounting open frame-free standing Wet Rack with sample preparation system, it is possible to add additional units as options. These include:
High-pressure needle valves
NW 6 mm, 400 bar, 630°C
High-pressure sample coolers
For boiler feed water and steam, design according to VGB/DGRL, alternatively ASTM. Made of high-quality stainless steel, sample coolers for temperatures up to 600°C and pressure up to 400 bar, sample flow up to 100 kg/h
Pressure regulator valve
Three different seat materials, three alternate orifice sizes and 7 pressure control ranges with INCONEL® diaphragms offer the user a wide spectrum of capabilities for pressure control with inlet pressures up to 6000 psig and standard operating temperatures up to 500° F (260° C).
Safety shut-off valve
The purpose of the Auto Safe is to protect the down-streamed analyzing system in the sample flow and personnel against extremely high thermal loading (loss or lack of cooling water) (mechanically or electrically actuated).
Second sample cooler for chilled water.
The tube-within-a-tube design also provides for high pressure/temperature capabilities on both sides of the heat exchanger, providing greater application flexibility. The single continuous inner tube increases reliability and cleanliness and allows the unit to be completely drainable. The second sample cooler is used with chilled water to reach temperature of sample in 25°C in according to ASME standard for SWASystem.
Chiller unit
Maintain sample temperature to 77°F (25°C) with water-cooled
temperature control unit or a closed-loop cooling water isolation skid.
Frame-free standing Wet Rack
Stand-alone frame with painted carbon steel construction suitable for indoor installation. Fabricated pre-wired in PSQ work shop with sample preparation.
Power supply
The system can be designed either for 115 V AC, 230 V AC or 400 V AC (-15 %, +10 %) with 50 or 60 Hz. Three phases, neutral and ground must be provided by the customer at 400 V AC.
Analyzers
Sampling and analyzing system with analyzers of well-known suppliers:
Hamilton, Knick, Emerson, Dr. Thiedig
For all typical measuring tasks as Cond., pH, O2, Na, SiO2, N2H4 etc.
Completely wired on control panel as interface to the DCS.
pH and conductivity
parameter |
measuring range |
Temperature sensor |
Ph |
0 – 14 pH |
Pt100 |
cond |
0.02 to 2000 µS/cm |
Pt1000 |
Dissolved oxygen
Dissolved oxygen monitoring is imperative in power stations using neutral or combined operating conditions (pH 7.0-7.5 or 8.0-8.5). The typical points in steam circuit where dissolved oxygen monitoring is required are deaerator inlet and outlet.
Component |
measuring range |
Temperature sensor |
DO |
1 ppb to 40 ppm |
NTC 22 kOhm |
Degassed Acid Conductivity
Acid conductivity
In cation filter, the H+ from the exchanged cations combine with OH- from alkalizing agents to water. The remaining conductivity is determined by the autoprotolysis of the pure water plus the impurities in the form of anions, i.e. also CO32-. To operate a steam turbine, the acid conductivity must not exceed a threshold of typically 0.2 µS/cm. The following causes for increased conductivity are possible:
Degassed Cation conductivity
For the shortest possible start-up phase, the acid conductivity must be measured without the influence of the conductivity caused by dissolved CO2. Thus the threshold for operation of the turbine is reached faster. The dissolved CO2 rises up the conductivity, but does not harm the turbine. Therefore, it is necessary to remove the carbonic acid from the sample and to measure the conductivity again (degassed acid conductivity).
Device |
Digox 6.1 HY-S |
measuring range |
Conductivity 0 – 1000 µS/cm, pH calculation from 7.5 - 10 |
Accuracy |
< [1 % of measuring value + 0,015 µS/cm] |
Silica (SiO2)
The determination of dissolved silicic acid (ortho-silicate) in the water steam cycle is of great importance for the operation and plant safety in power plants. In addition to the determination of ortho-silicate in the live steam in order to avoid deposits or crystallisation inside the turbine, it is possible to detect an aperture in the anion filter or mixed bed exchanger.
Device |
Digox 602 silica |
measuring range |
0 – 5000 ppb SiO2 |
Photometer |
precision photometer with temperature control of the sample |
Accuracy |
Max. {± 2 % of reading or ± 2 ppb} within measuring range 0 – 100 ppb |
Sodium (Na)
The determination of sodium in low concentrations in the water-steam cycle is of great importance in power plants. On the one hand, this is due to the fact that the significance of sodium in corrosion processes has become more and more recognized over the last few years. On the other hand, this measurement procedure enables a fast monitoring of a leakage for instance in the condenser or the aperture in a cation filter or a mixed bed filter.
Device |
Digox 602 sodium |
measuring range |
0.1 – 2000 ppb Na |
Measuring principle |
potential measurement of an ion-sensitive Na-electrode against a reference electrode |
Accuracy |
Maximum {±2 % of reading or ±2 ppb} |
Technical Specifications
Climatic conditions
Ambient temperature 0 ... 35 °C
Relative humidity 70%, non-condensing
Corrosive atmosphere No
Sample inlet conditions
Max. Sample pressure at inlet to 400 bar
sample preparation system
Max. Sample temperature at inlet to 550 °C
sample preparation system
design pressure 245 bar at 550°C
Sample flow [kg/h] 60
Medium Steam or liquid
Connections
Tube material SST or CS
Cables Not armored, not halogen-free
Electrical design According to IEC
Cable ID Individual core labeling as
System design
Ex zone Non-hazardous
Version Mounting frame
Automatic calibration Yes(just for sodium and silica)
Dimensions (without plinth)
Size Depended on quantity of stream
More information in the catalog link above
(98) 21 44443999 داخلی 116
(98) 21 44444950 داخلی 116
info[AT]piramoonco.com
145 Shahid Mokhberi St. Sattari Hwy.,Tehran, Iran
(98) 76 35340394
info[AT]piramoonco.com
Tula Industrial Park, Cable site
post box : 567-14455
postal code : 1475877134
info[AT]piramoonco.com
145 Shahid Mokhberi St. Sattari Hwy.,Tehran, Iran